K2 Configuration |
|||||||||||||||
|
|
|||||||||||||||
|
Equipment Required Laptop Computer W/Serial port and Altus Quicktalk Installed RS-232c cable to link to laptop |
|||||||||||||||
|
This section discusses the Configuration of the Altus K2 Recorder in the Strong Motion Network. |
NOTE: You will need Kinemetrics QuickTalk installed on your laptop to proceed with these instructions |
||||||||||||||
|
|
<This is the main window when Quicktalk is opened. <Select the Recorder pull down menu and Acquisition Control from that menu. Select Stop Acquisition.> Select Edit Parameters.> |
|
|||||||||||||||||||
|
|
<Edit Parameters Window <Click From Recorder Select Station Station Parameters Window> Station ID: Three digit station code> De-select Channel 4> Click OK (returns to edit parameter window)> |
|
|||||||||||||||||||
|
|
Select Streams at edit parameter window <Stream Parameters Window <Pre-event Storage Time: 15 <Post Event Storage Time: 30 <Sample Rate: 100 <Click Ok (returns to edit parameter window) Select Serial Data at edit parameter window Serial Data Streams Transmission Window> Deselect Channel 4> Transmit Sample Rate: 100 S.P.S.> Click OK (returns to edit parameter window)> |
|
|||||||||||||||||||
|
|
Select Channels at edit parameter window <Channel 1- <Alarm Trigger .25 <Threshold Trigger .25 <Threshold De-trigger .25 Click Next |
<Channel 2- <Alarm Trigger .25 <Threshold Trigger .25 <Threshold De-trigger .25 Click Next |
Channel 3- <Alarm Trigger .5 <Threshold Trigger .5 <Threshold De-trigger .2 Click OK |
|
|||||||||||||||||
|
|
At Edit Parameters Window <Click To Recorder <Click Close Click Start Acquisition> Click Close> |
|
|||||||||||||||||||
|
Congratulations, you have just configured the K2 for Serial Data Streaming. Back to: Building Installation - Field Installation |
|||||||||||||||||||||
|