K2 Configuration

Equipment Required

Laptop Computer W/Serial port and Altus Quicktalk Installed

RS-232c cable to link to laptop

This section discusses the Configuration of the Altus K2 Recorder in the Strong Motion Network.

NOTE: You will need Kinemetrics QuickTalk installed on your laptop to proceed with these instructions

<This is the main window when Quicktalk is opened.

<Select the Recorder pull down menu and Acquisition Control from that menu.

Select Stop Acquisition.>

Select Edit Parameters.>

 
 

<Edit Parameters Window

<Click From Recorder

Select Station

Station Parameters Window>

Station ID: Three digit station code>

De-select Channel 4>

Click OK (returns to edit parameter window)>

 
 

Select Streams at edit parameter window

<Stream Parameters Window

<Pre-event Storage Time: 15

<Post Event Storage Time: 30

<Sample Rate: 100

<Click Ok (returns to edit parameter window)

Select Serial Data at edit parameter window

Serial Data Streams Transmission Window>

Deselect Channel 4>

Transmit Sample Rate: 100 S.P.S.>

Click OK (returns to edit parameter window)>

 

 

 

 

 

 
 

Select Channels at edit parameter window


<Channel 1-

<Alarm Trigger .25

<Threshold Trigger .25

<Threshold De-trigger .25

Click Next

 

 

<Channel 2-

<Alarm Trigger .25

<Threshold Trigger .25

<Threshold De-trigger .25

Click Next

 

 

Channel 3-

<Alarm Trigger .5

<Threshold Trigger .5

<Threshold De-trigger .2

Click OK

 

 
 

At Edit Parameters Window

<Click To Recorder

<Click Close

Click Start Acquisition>

Click Close>

Congratulations, you have just configured the K2 for Serial Data Streaming.